US Electric Motors
Sort By
Refine Your Search
Material
Overall Diameter
Bore Diameter
Number of Blades
Showing 1–19 of 24 results
-
Part # U-347274
10-1/2″ OD Fan
×- Overall Diameter (D) - in.
- 10.5
- Bore Diameter - in.
- 1.25"
- Bore Diameter - mm.
- 31.75mm
- Number of Blades
- 14
- Material
- Plastic
- Weight - lbs
- 0.79
-
Part # U-362253
10-3/8″ OD Fan
×- Overall Diameter (D) - in.
- 10.375
- Bore Diameter - in.
- 1.625"
- Bore Diameter - mm.
- 41.275mm
- Number of Blades
- 12
- Material
- Plastic
- Suggested for Frame
- 280T
- Poles
- 4, 6
- Weight - lbs
- 0.79
-
Part # U-375604
10-5/8″ OD Fan
×- Overall Diameter (D) - in.
- 10.625
- Bore Diameter - in.
- 2.375"
- Bore Diameter - mm.
- 60.325mm
- Keyway Size - in.
- 3/8" x 7/32"
- Keyway Size - mm.
- 9.525 x 5.55625mm
- Number of Blades
- 12
- Material
- Plastic
- Weight - lbs
- 0.79
-
Part # U-370428
11-1/8″ OD Fan
×- Overall Diameter (D) - in.
- 11.125
- Bore Diameter - in.
- 1.375"
- Bore Diameter - mm.
- 34.925mm
- Keyway Size - in.
- 5/16" x 5/32"
- Keyway Size - mm.
- 7.9375 x 3.96875mm
- Number of Blades
- 14
- Material
- Plastic
- Weight - lbs
- 0.74
-
Part # U-171602
11-1/8″ OD Fan
×- Overall Diameter (D) - in.
- 11.125
- Bore Diameter - in.
- 1.25"
- Bore Diameter - mm.
- 31.75mm
- Number of Blades
- 14
- Material
- Plastic
- Suggested for Frame
- 250T, 280T
- Poles
- 4, 6
- Weight - lbs
- 0.67
-
Part # U-362254
13″ OD Fan
×- Overall Diameter (D) - in.
- 13
- Bore Diameter - in.
- 1.875"
- Bore Diameter - mm.
- 47.625mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 12
- Material
- Plastic
- Suggested for Frame
- 320T
- Poles
- 4, 6
- Weight - lbs
- 1.05
-
Part # U-362255
14″ OD Fan
×- Overall Diameter (D) - in.
- 14
- Bore Diameter - in.
- 2.125"
- Bore Diameter - mm.
- 53.975mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 12
- Material
- Plastic
- Suggested for Frame
- 360T
- Poles
- 4, 6
- Weight - lbs
- 1.13
-
Part # U-375607
16″ OD Fan
×- Overall Diameter (D) - in.
- 16
- Bore Diameter - in.
- 2.375"
- Bore Diameter - mm.
- 60.325mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 12
- Material
- Plastic
- Suggested for Frame
- 400T
- Poles
- 4, 6
- Weight - lbs
- 1.53
-
Need something Custom? We can make it in the foundry.
Learn More -
Part # U-375880
18″ OD Fan
×- Overall Diameter (D) - in.
- 18
- Bore Diameter - in.
- 2.375"
- Bore Diameter - mm.
- 60.325mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 16
- Material
- Plastic
- Suggested for Frame
- 440T
- Poles
- 4, 6
- Weight - lbs
- 2.00
-
Part # U-375882
19-7/8″ OD Fan
×- Overall Diameter (D) - in.
- 19.875
- Bore Diameter - in.
- 2.375"
- Bore Diameter - mm.
- 60.325mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 16
- Material
- Plastic
- Suggested for Frame
- 449T
- Poles
- 4, 6
- Weight - lbs
- 2.46
-
Part # U-84591
5-1/4″ OD Fan
×- Overall Diameter (D) - in.
- 5.25
- Bore Diameter - in.
- 0.5625"
- Bore Diameter - mm.
- 14.2875mm
- Number of Blades
- 6
- Material
- Aluminum
- Suggested for Frame
- 56
- Poles
- 2, 4, 6
- Weight - lbs
- 0.05
-
Part # U-108604
5-3/4″ OD Fan
×- Overall Diameter (D) - in.
- 5.75
- Bore Diameter - in.
- 0.875"
- Bore Diameter - mm.
- 22.225mm
- Keyway Size - in.
- 3/16" x 3/32"
- Keyway Size - mm.
- 4.7625 x 2.38125mm
- Number of Blades
- 8
- Material
- Plastic
- Weight - lbs
- 0.05
-
Part # U-141809
5-5/8″ OD Fan
×- Overall Diameter (D) - in.
- 5.625
- Bore Diameter - in.
- .660"
- Bore Diameter - mm.
- 16.764mm
- Keyway Size - in.
- 1/8" x 1/16"
- Keyway Size - mm.
- 3.175 x 1.5875mm
- Number of Blades
- 12
- Material
- Plastic
- Suggested for Frame
- 56, 140T
- Poles
- 2, 4, 6
- Weight - lbs
- 0.05
-
Part # U-360240
6-7/8″ OD Fan
×- Overall Diameter (D) - in.
- 6.875
- Bore Diameter - in.
- 0.875"
- Bore Diameter - mm.
- 22.225mm
- Number of Blades
- 8
- Material
- Plastic
- Weight - lbs
- 0.25
-
Part # U-360276
6-7/8″ OD Fan
×- Overall Diameter (D) - in.
- 6.875
- Bore Diameter - in.
- 1.125"
- Bore Diameter - mm.
- 28.575mm
- Number of Blades
- 8
- Material
- Plastic
- Suggested for Frame
- 180T
- Poles
- 2
- Weight - lbs
- 0.23
-
Part # U-375602
7-1/4″ OD Fan
×- Overall Diameter (D) - in.
- 7.25
- Bore Diameter - in.
- 1.25"
- Bore Diameter - mm.
- 31.75mm
- Number of Blades
- 8
- Material
- Plastic
- Suggested for Frame
- 250T
- Weight - lbs
- 0.19
-
Part # U-375606
8-1/2″ OD Fan
×- Overall Diameter (D) - in.
- 8.5
- Bore Diameter - in.
- 2.125"
- Bore Diameter - mm.
- 53.975mm
- Keyway Size - in.
- 3/8" x 3/16"
- Keyway Size - mm.
- 9.525 x 4.7625mm
- Number of Blades
- 16
- Material
- Plastic
- Suggested for Frame
- 360T
- Poles
- 2
- Weight - lbs
- 0.64
-
Part # U-370427
8-1/8″ OD Fan
×- Overall Diameter (D) - in.
- 8.125
- Bore Diameter - in.
- 1.375"
- Bore Diameter - mm.
- 34.925mm
- Keyway Size - in.
- 5/16" x 5/32"
- Keyway Size - mm.
- 7.9375 x 3.96875mm
- Number of Blades
- 14
- Material
- Plastic
- Weight - lbs
- 0.55
WE’RE HERE TO HELP WITH QUESTIONS BIG AND SMALL.
Ask JenkinsElectric Motor Fan Blade Replacement
At Jenkins, electric motor fan replacement is easy thanks to our 3,000+ replacement parts library. We offer an extensive variety of Jenkins aluminum replacement fans, OEM fans and aluminum OEM replacement fans. Can’t find what you’re looking for? We can also cast hard-to-find parts or electric motor fan blade replacements with short leads times and no minimums in our in-house foundry.
How do I know which replacement fan I need?
There’s a lot to consider when trying to identify the right electric motor fan replacement. At Jenkins, we can simplify finding a replacement fan. The critical measurements for finding a suitable replacement fan are; blade width, outside diameter, hub recess, bore diameter and keyway dimensions. Please click here for our fan identification worksheet. Have more questions about which replacement fan you need? Just call Jenkins (800) 438-3003 or click here to ask your question about motor fan replacements.
How do I replace my fan?
When it comes time for an electric motor cooling fan replacement, Jenkins aluminum fans are durable and long lasting. To install or remove an aluminum fan, warm it with a torch or in an oven, and slip it on the shaft. For technical questions, Just call Jenkins (800) 438-3003 or click here to ask your question about motor fan replacements.
How do you cool an electric motor?
Electric motor cooling fans are used to reduce and regulate temperatures on electric motors. To determine how effective a motor cooling fan is, volume, static pressure, and altitude are all considered. In other words, how much air it moves and at what pressure. Other factors considered in calculating the effectiveness are the use of variable frequency drives (VFDs), trimming or machining the impeller, and the use of fan covers. When determining the effectiveness of an electric motor cooling fan a skilled Jenkins technician can help you through the process of choosing the right fan to cool your electric motor. Just call Jenkins (800) 438-3003 or click here to ask your question about motor cooling fans.
Can you replace just fan blades?
Yes, you are able to replace a fan blade if it is a bolt-on style attachment. This is a rare type of motor fan blade attachment style. The most common type of cooling fan is a single, complete cast part. If your electric motor cooling fan needs a blade replacement, a Jenkins Customer Service Specialist will help guide you to the right replacement fan. Just call Jenkins (800) 438-3003 or click here to ask your question about motor cooling fans.
What happens if a fan loses a blade?
If a fan loses a blade it needs to be replaced immediately. A decrease in the cooling efficiency and the resulting unbalanced rotor would be dangerous and catastrophic to your electric motor. If your electric motor cooling fan needs a blade replacement, a Jenkins Customer Specialist will help guide you to the right replacement fan. Just call Jenkins (800) 438-3003 or click here to ask your question about motor cooling fans.